Power Supply Information
Selecting a specific power supply opens the Power Supply Information—Bay x page, where x is the bay of the selected power supply. This screen provides status information on the selected power supply.
Status information
Row |
Description |
---|---|
Status |
The overall status of the power supply. Possible values are Unknown, OK, Degraded, and Critical Error. |
Input Status |
The input status of the power supply. Possible values are Unknown, OK, Degraded, and Critical Error. |
Present Output |
The amount of power provided by the power supply in AC or DC mode. This value is displayed in watts |
Output Capacity |
The maximum amount of power that can be provided by the power supply in AC or DC mode. This value is displayed in watts. |
Model |
The power supply model name. |
Serial Number |
The unique serial number of the power supply. |
Part Number |
The part number to be used when ordering an additional or replacement power supply of this type. |
Spare Part Number |
The spare part number to be used when ordering an additional or replacement power supply. |
Diagnostic Information
Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a failure has occurred) or is sent by the device microcontroller, without being polled to report a failure.
Row |
Description |
---|---|
Device Identification Data |
The device identification data checked is information such as model name, part number, serial number, and other information used to identify the device. This data is also referred to as FRU data. A device identification data error appears if the data is not present or not readable by the Onboard Administrator. Possible values are OK or Error. |
Device Location |
Incorrect power supply location. Possible values are OK or Incorrect location for proper device cooling. |
Device Operational |
Device has failed; status was not requested by the Onboard Administrator. Possible values are OK and Error. |
Device Degraded |
Device has failed; status was requested by the Onboard Administrator. Possible values are OK and Error. |
Power Cord |
Input power status. Possible values are OK and Error. |
Device Mismatch |
This field indicates different power supply models are installed in the same enclosure and you need to install the same power supply models in each bay. |
Service Action |
Recommended service action required to correct a power supply error. |