Enclosure Settings screen
This section provides detailed procedures to configure the management functionalities provided by the Onboard Administrator.
To view the enclosure Status screen, from the tree view, select Enclosure Information.
Status overview
Row |
Description |
---|---|
Enclosure Status |
The overall status of the enclosure. Possible values are Unknown, OK, Degraded, and Failed. |
Active OA Status |
The overall status of the Active Onboard Administrator. Possible values are Unknown, OK, Degraded, and Failed. |
Standby OA Status |
The overall status of the Standby Onboard Administrator. Possible values are Absent, Unknown, OK, Degraded, and Failed. |
Enclosure Power Mode |
The power redundancy mode. Possible values are AC Redundant, Power Supply Redundant, Not Redundant, or Unknown. For information on these modes, see the HP BladeSystem c7000 User Guide. |
Diagnostic Information
Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a failure has occurred) or is sent by the device microcontroller, without being polled to report a failure.
Row |
Description |
---|---|
Device Identification Data |
Contains information on model name, part number, serial number, and other information used to identify the device. This data is also referred to as FRU data. Device identification data error displays if the data is not present or not readable by the Onboard Administrator. |
Redundancy |
Possible values are OK or Error. An error indicates the redundant Onboard Administrators are having problems syncing up. Check the syslog for errors. Possible reasons for the error are mismatched firmware or a software or hardware failure. |
Enclosure Status Overview
Subsystems and Devices |
Description |
---|---|
Device Bay Overview |
The overall status of all device bays. The status is an aggregate status of all the devices in the enclosure. If more than one device has a status other than OK, then they are displayed in a list in this table. |
Interconnect Bay Overview |
The overall status of the interconnect bays. The status is an aggregate status of all the interconnects in the enclosure. If more than one interconnect has a status other than OK, then they are displayed in a list in this table. |
Power Subsystem |
The overall status of the Power Subsystem of the enclosure. The status is an aggregate status of all the power supplies in the enclosure. If more than one power supply has a status other than OK, then they are displayed in a list in this table. |
Thermal Subsystem |
The overall status of the Thermal Subsystem of the enclosure. The status is an aggregate status of all the fans in the enclosure. If more than one fan has a status other than OK, then they are displayed in a list in this table. |
Information
Column |
Description |
---|---|
Part |
The name of the part |
Model |
The model number of the part |
Manufacturer |
The name of the company that manufactured the part |
Serial Number |
The unique serial number of the part |
Part Number |
The part number to be used when ordering an additional part. The Power Input Module has no part number and always shows N/A in the Part Number column. |
Spare Part Number |
The part number to be used when ordering a replacement part |
Changing Settings
You can change enclosure settings from this screen. To save the settings after making changes, click Apply.
Field |
Possible value |
Description |
---|---|---|
Enclosure Name |
1 to 32 characters including all alphanumeric characters, the dash (-), and the underscore (_) |
The name of the selected enclosure |
Rack Name |
1 to 32 characters including all alphanumeric characters, the dash (-), and the underscore (_) |
The name of the rack in which the enclosure is installed |
Asset Tag |
0 to 32 characters including all alphanumeric characters, the dash (-), and the underscore (_) |
The asset tag is used for inventory control. The default asset tag is blank |
Virtual Buttons
To change the state of the enclosure UID light, which is located next to the enclosure link and Onboard Administrator/iLO connections, click Toggle On/Off.
Component Firmware
Column |
Description |
---|---|
Bay |
The device bay within the enclosure |
Device Model |
The model number of the device |
Current Firmware Version |
The installed firmware version of the device |
Available Firmware Version |
The latest version of firmware currently available for the device |