Enclosure Settings screen

This section provides detailed procedures to configure the management functionalities provided by the Onboard Administrator.

To view the enclosure Status screen, from the tree view, select Enclosure Information.

HP BladeSystem 112311 Enclosure Settings screen

Status overview

Row

Description

Enclosure Status

The overall status of the enclosure. Possible values are Unknown, OK, Degraded, and Failed.

Active OA Status

The overall status of the Active Onboard Administrator. Possible values are Unknown, OK, Degraded, and Failed.

Standby OA Status

The overall status of the Standby Onboard Administrator. Possible values are Absent, Unknown, OK, Degraded, and Failed.

Enclosure Power Mode

The power redundancy mode. Possible values are AC Redundant, Power Supply Redundant, Not Redundant, or Unknown. For information on these modes, see the HP BladeSystem c7000 User Guide.

Diagnostic Information

Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a failure has occurred) or is sent by the device microcontroller, without being polled to report a failure.

Row

Description

Device Identification Data

Contains information on model name, part number, serial number, and other information used to identify the device. This data is also referred to as FRU data. Device identification data error displays if the data is not present or not readable by the Onboard Administrator.

Redundancy

Possible values are OK or Error. An error indicates the redundant Onboard Administrators are having problems syncing up. Check the syslog for errors. Possible reasons for the error are mismatched firmware or a software or hardware failure.

Enclosure Status Overview

Subsystems and Devices

Description

Device Bay Overview

The overall status of all device bays. The status is an aggregate status of all the devices in the enclosure. If more than one device has a status other than OK, then they are displayed in a list in this table.

Interconnect Bay Overview

The overall status of the interconnect bays. The status is an aggregate status of all the interconnects in the enclosure. If more than one interconnect has a status other than OK, then they are displayed in a list in this table.

Power Subsystem

The overall status of the Power Subsystem of the enclosure. The status is an aggregate status of all the power supplies in the enclosure. If more than one power supply has a status other than OK, then they are displayed in a list in this table.

Thermal Subsystem

The overall status of the Thermal Subsystem of the enclosure. The status is an aggregate status of all the fans in the enclosure. If more than one fan has a status other than OK, then they are displayed in a list in this table.

Information

HP BladeSystem 112314 Enclosure Settings screen

Column

Description

Part

The name of the part

Model

The model number of the part

Manufacturer

The name of the company that manufactured the part

Serial Number

The unique serial number of the part

Part Number

The part number to be used when ordering an additional part. The Power Input Module has no part number and always shows N/A in the Part Number column.

Spare Part Number

The part number to be used when ordering a replacement part

Changing Settings

You can change enclosure settings from this screen. To save the settings after making changes, click Apply.

Field

Possible value

Description

Enclosure Name

1 to 32 characters including all alphanumeric characters, the dash (-), and the underscore (_)

The name of the selected enclosure

Rack Name

1 to 32 characters including all alphanumeric characters, the dash (-), and the underscore (_)

The name of the rack in which the enclosure is installed

Asset Tag

0 to 32 characters including all alphanumeric characters, the dash (-), and the underscore (_)

The asset tag is used for inventory control.

The default asset tag is blank

Virtual Buttons

To change the state of the enclosure UID light, which is located next to the enclosure link and Onboard Administrator/iLO connections, click Toggle On/Off.

HP BladeSystem 119727 Enclosure Settings screen

Component Firmware

HP BladeSystem 124292 Enclosure Settings screen

Column

Description

Bay

The device bay within the enclosure

Device Model

The model number of the device

Current Firmware Version

The installed firmware version of the device

Available Firmware Version

The latest version of firmware currently available for the device

Enclosure Settings screen