Interconnect Bay screen
The Interconnect Bay screen displays information about the bays where switches and routers can be placed. Also, you can view the Onboard Administrator modules.
Click the Port Mapping Interconnect link to display port mapping information on the interconnect bay you have selected. The port mapping information can also be selected from the navigation tree.
Status information
Row |
Description |
---|---|
Status |
The overall status of the interconnect device. Possible values are Unknown, OK, Degraded, and Failed. |
Thermal Status |
The thermal status of the interconnect device. Possible values are Unknown, OK, Degraded, and Failed. |
Powered |
The power state of the interconnect device. Possible values are On or Off. |
Diagnostic Information
Row |
Description |
---|---|
Device Identification Data |
Contains information on model name, part number, serial number, and other information used to identify the device. This data is also referred to as FRU data. Device identification data error displays if the data is not present or not readable by the Onboard Administrator. |
Management Processor |
Management processor is not responding. Possible values are OK or Error. |
Temperature |
Temperature is above the warning threshold. Possible values are OK or Temperature Warning. |
Overheat Check |
Temperature is above the danger threshold. Possible values are OK or Critical temperature threshold reached. |
Device Operational |
Device has failed; status was not requested by the Onboard Administrator. Possible values are OK or Error. |
Device Degraded |
Device has failed; status was requested by the Onboard Administrator. Possible values are OK or Error. |