Active Onboard Administrator screen
On the Active Onboard Administrator screen under the Status and Information tab, three tables provide detailed information about your Onboard Administrator.
Status and Information tab
NOTE: Accessing the Active OA through a link-local IPv6 address might not work on all client system setups containing multiple network interfaces. |
Status information
Row |
Description |
---|---|
Status |
The overall status of the enclosure. Possible values are Unknown, OK, Degraded, and Failed. |
Role |
Active or Standby |
Bay Number |
The physical bay number where the Onboard Administrator is installed. |
Temperature |
The temperature of the enclosure in degrees Fahrenheit and Celsius. |
Caution Threshold |
The temperature at which the enclosure will report a status of caution. |
Critical Threshold |
The temperature at which the enclosure will report a critical status and will shut down. |
Hardware information
Row |
Description |
---|---|
Device Name |
The common descriptive name of the Onboard Administrator |
Manufacturer |
The name of the company that manufactured the Onboard Administrator |
Firmware Version |
The version of the firmware image in the Onboard Administrator |
Hardware Version |
The version of the enclosure hardware. |
Part Number |
The part number to be used when ordering an additional or replacement Onboard Administrator |
Spare Part Number |
The spare part number to be used when ordering an additional or replacement Onboard Administrator |
Serial Number |
The unique serial number of the Onboard Administrator |
Diagnostic information
Row |
Description |
---|---|
Device Identification Data |
This row displays information such as model name, part number, serial number, and other information used to identify the device. This data is also referred to as FRU data. A device identification data error appears if the data is not present or not readable by the Onboard Administrator. Possible values are OK or Error. |
Firmware Mismatch |
The Onboard Administrator with the lowest firmware version displays this field when two Onboard Administrators are present. |
Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a failure has occurred) or is sent by the device microcontroller, without being polled, to report a failure.