Device bay port mapping table for c3000 Enclosure

If a device is not present, the checkbox is disabled and the port cannot be viewed.

The server blades are mapped to the interconnect bays in the following manner. The terms 1x/2x or 4x refer to the number of interconnect lanes per port provided by the mezzanine card.

Half-height server blade

The following table lists the available configurations for half-height devices installed in device bay N (1-8).

Connection

Port number

Connects to interconnect bay/port

Comments

Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

1/Port N

1/Port N+8

One single-wide Ethernet interconnect module

Mezzanine slot 1—1x or 2x cards (4x cards are not supported in this slot)

1x/2x port 1

1x/2x port 2

2/Port N

2/Port N+8

  • One single-wide interconnect module
  • Only two ports will be connected.
  • Four port cards will only connect the first two ports.

Mezzanine slot 2—1x or 2x cards

1x/2x port 1

1x/2x port 2

1x/2x port 3

1x/2x port 4

3/Port N

4/Port N

3/Port N+8

4/Port N+8

One or two single-wide interconnect modules

Mezzanine slot 2—4x cards

4x port 1

4x port 2

3/Port N

3/Port N+8

One double-wide interconnect module

Full-height server blade

The following table lists the available configurations for full-height devices installed in device bay N (1-4).

Connection

Port number

Connects to interconnect bay/port

Comments

Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

NIC 3 (Port:3)

NIC 4 (Port:4)

1/Port N+4

1/Port N+12

1/Port N

1/Port N+8

One single-wide Ethernet interconnect module

Mezzanine slot 1—1x or 2x cards (4x cards are not supported in this slot)

1x/2x port 1

1x/2x port 2

1x/2x port 3

1x/2x port 4

2/Port N

2/Port N+8

2/Port N+4

2/Port N+12

One single-wide interconnect module

Mezzanine slot 2—1x or 2x cards

1x/2x port 1

1x/2x port 2

1x/2x port 3

1x/2x port 4

3/Port N

4/Port N

3/Port N+8

4/Port N+8

One or two single-wide interconnect modules

Mezzanine slot 2—4x cards

4x port 1

4x port 2

3/Port N

3/Port N+8

One double-wide interconnect module

Mezzanine slot 3—1x or 2x cards

1x/2x port 1

1x/2x port 2

1x/2x port 3

1x/2x port 4

3/Port N+12

4/Port N+12

3/Port N+4

4/Port N+4

One or two single-wide interconnect modules

Mezzanine slot 3—4x cards

4x port 1

4x port 2

3/Port N+12

3/Port N+4

One double-wide interconnect module

Double dense server blade

The following table lists the available configurations for double dense devices installed in device bay N (1-8).

Connection

Port Number

Connects to interconnect bay/port

Server A Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

1/Port N

2/Port N

Server A Mezzanine

Port 1

Port 2

3/Port N

4/Port N

Server B Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

1/Port N+8

2/Port N+8

Server B Mezzanine

Port 1

Port 2

3/Port N+8

4/Port N+8

AMC Telco I/O expansion blade

The table lists the available configurations for AMC Telco devices installed in device bay N (1-8).

Connection

Port Number

Connects to interconnect bay/port

AMC Embedded (1)

Port 1

Port 3

1/Port N

2/Port N

AMC Embedded (2)

Port 5

Port 7

3/Port N

4/Port N

HP ProLiant BL2x220c G7 Server

The following table lists the available configurations for ProLiant BL2x220c G7 devices installed in c3000 device bay N (1-8).

Connection

Port Number

Connects to interconnect bay/port

Server A Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

1/Port N

2/Port N

Server A NC543i*

Port 1

3/Port N

Server B Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

1/Port N+8

2/Port N+8

Server B NC543i*

Port 1

3/Port N+8

*The ProLiant BL2x220c G7 Server embedded NC543i is automatically configured by the Onboard Administrator to Ethernet, if an Ethernet interconnect module is installed in bay 3, or to IB if a double-wide IB interconnect is installed in bay 3. To change the NC543i configuration from one type to another, power off all the ProLiant BL2x220c G7 Servers, and replace the interconnect module with the other type. Reboot the active Onboard Administrator or reseat all the ProLiant BL2x220c G7 Servers and the Onboard Administrator reconfigures all the embedded NC543i for the new interconnect type.

HP ProLiant BL680c G7 Server

The following table lists the port mapping for the ProLiant BL680c G7 server blades installed in c3000 device bay N (2 or 4).

Connection

Port Number

Connects to interconnect bay/port

A-Side Embedded NIC

NIC 1

NIC 2

NIC 3

NIC 4

1/Port N+4

1/Port N+12

1/Port N

1 Port N+8

B-Side Embedded NIC

NIC 5

NIC 6

1/Port N+3

2/Port N+11

A-Side Mezzanine 1

Port 1

Port 2

Port 3

Port 4

2/Port N

2/Port N+8

2/Port N+4

2/Port N+12

A-Side Mezzanine 2

Port 1

Port 2

Port 3

Port 4

3/Port N

4/Port N

3/Port N+8

4/Port N+8

A-Side Mezzanine 3

Port 1

Port 2

Port 3

Port 4

3/Port N+12

4/Port N+12

3/Port N+4

4/Port N+4

B-Side Mezzanine 4

Port 1

Port 2

Port 3

Port 4

3/Port N+7

4/Port N+7

2/Port N-1

2/Port N-1

B-Side Mezzanine 5

Port 1

Port 2

Port 3

Port 4

2/Port N+3

2/Port N+11

2/Port N-1

2/Port N+7

B-Side Mezzanine 6

NIC only

Port 1

Port 2

1/Port N-1

1/Port N+7

B-Side Mezzanine 7

Port 1

Port 2

Port 3

Port 4

3/Port N+3

4/Port N+3

3/Port N+11

4/Port N+11

Device bay port mapping table for c3000 Enclosure