Device bay port mapping table for c7000 Enclosure

If a device is not present, the checkbox is disabled and the port cannot be viewed.

The server blades are mapped to the interconnect bays in the following manner. The terms 1x/2x or 4x refer to the number of interconnect lanes per port provided by the controller. The more lanes provided per port, the higher the data transmission rate coming from that port.

Half-height server blade

The following table lists the port mapping for half-height server blades installed in c7000 device bay N (1-16).

Connection

Port number

Connects to interconnect bay/port

Embedded NIC

NIC 1

NIC 2

1/Port N

2/Port N

Mezzanine 1

Port 1

Port 2

3/Port N

4/Port N

Mezzanine 2

Port 1

Port 2

Port 3

Port 4

5/Port N

6/Port N

7/Port N+8

8/Port N+8

Full-height server blade

The following table lists the port mapping for full-height server blades installed in device bay N (1-8).

Connection

Port number

Connects to interconnect bay/port

Embedded NIC

NIC 1

NIC 2

NIC 3

NIC 4

1/Port N+8

2/Port N+8

1/Port N

2/Port N

Mezzanine 1

Port 1

Port 2

Port 3

Port 4

3/Port N

4/Port N

3/Port N+8

4/Port N+8

Mezzanine 2

Port 1

Port 2

Port 3

Port 4

5/Port N

6/Port N

7/Port N

8/Port N

Mezzanine 3

Port 1

Port 2

Port 3

Port 4

7/Port N+8

8/Port N+8

5/Port N+8

6/Port N+8

Double dense server blade

The following table lists the available configurations for double dense devices installed in device bay N (1-16).

Connection

Port Number

Connects to interconnect bay/port

Server A Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

1/Port N

3/Port N

Server A Mezzanine*

Port 1

Port 2

5/Port N

6/Port N

Server B Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

2/Port

4/Port N

Server B Mezzanine*

Port 1

Port 2

7/Port N

8/Port N

AMC Telco I/O expansion blade

The table lists the available configurations for AMC Telco devices installed in device bay N (1-16).

Connection

Port Number

Connects to interconnect bay/port

AMC Embedded (1)

Port 1

Port 2

Port 3

Port 4

1/Port N

2/Port N

3/Port N

4/Port N

AMC Embedded (2)

Port 5

Port 6

Port 7

Port 8

5/Port N

6/Port N

7/Port N

8/Port N

HP ProLiant BL2x220c G7 Server

The following table lists the available configurations for ProLiant BL2x220c G7 devices installed in c7000 device bay N (1-8).

Connection

Port Number

Connects to interconnect bay/port

Server A Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

1/Port N

3/Port N

Server A NC543i*

Port 1

5/Port N

Server B Embedded NIC

NIC 1 (Port:1)

NIC 2 (Port:2)

2/Port N

4/Port N

Server B NC543i*

Port 1

7/Port N

*The ProLiant BL2x220c G7 Server embedded NC543i is automatically configured by the Onboard Administrator to Ethernet, if Ethernet interconnect modules are installed in bays 5 and 6, or to IB if a double-wide IB interconnect is installed in bay 5. To change the NC543i configuration from one type to another, power off all the ProLiant BL2x220c G7 Servers, and replace the interconnect module with the other type. Reboot the active Onboard Administrator or reseat all the ProLiant BL2x220c G7 Servers and the Onboard Administrator reconfigures all the embedded NC543i for the new interconnect type.

HP ProLiant BL680c G7 Server

The following table lists the port mapping for the ProLiant BL680c G7 server blades installed in c7000 device bay N (2, 4, 6, or 8).

Connection

Port Number

Connects to interconnect bay/port

A-Side Embedded NIC

NIC 1

NIC 2

NIC 3

NIC 4

1/Port N+8

2/Port N+8

1/Port N

2/Port N

B-Side Embedded NIC

NIC 5

NIC 6

1/Port N+7

2/Port N+7

A-Side Mezzanine 1

Port 1

Port 2

Port 3

Port 4

3/Port N

4/Port N

3/Port N+8

4/Port N+8

A-Side Mezzanine 2

Port 1

Port 2

Port 3

Port 4

5/Port N

6/Port N

7/Port N

8/Port N

A-Side Mezzanine 3

Port 1

Port 2

Port 3

Port 4

7/Port N+8

8/Port N+8

5/Port N+8

6/Port N+8

B-Side Mezzanine 4

Port 1

Port 2

Port 3

Port 4

7/Port N-1

8/Port N-1

5/Port N-1

6/Port N-1

B-Side Mezzanine 5

Port 1

Port 2

Port 3

Port 4

3/Port N+7

4/Port N+7

3/Port N-1

4/Port N-1

B-Side Mezzanine 6

NIC only

Port 1

Port 2

1/Port N-1

2/Port N-1

B-Side Mezzanine 7

Port 1

Port 2

Port 3

Port 4

5/Port N+7

6/Port N+7

7/Port N+7

8/Port N+7

Device bay port mapping table for c7000 Enclosure